This station is used for performance and fatigue tests of sub parts. There is a special platform for displacement - force controlled linear and rotary motion.
This station is used for performance and fatigue tests of sub parts . There is a special platform for displacement - force controlled linear and rotary motion. Linear and rotary motions can be applied and controlled separately or simultaneously. Linear actuator has a 25 kN / ±75 mm and Rotary actuator has a 226 N.m / ± 45º capacity.